Product Introduction
Typical Application
• Methanol, ethanol, propanol
• Acetone, acetonitrile
• Hexane
• Ethyl acetate
• Tetrahydrofuran THF
• Dimethylformamide DMF
__________________________________________________________________________________
Product Description
• Molecular Cut-off: 100da
• RO Water Flux: 65 L/m2/h
• MgSO4 Rejection Rate: ≥ 99.5 %
__________________________________________________________________________________
Operating Information
• Maximum Operating Pressure: 70bar
• Maximum Pressure Drop: 0.5bar
• Maximum Operating Temperature: Operation : 60 °C Clean: 60 °C
• Allowable pH : Operation : 2 - 12 Clean: 1 - 13
• Recirculation Flow Rate:
2540:7.5 – 19 L/min
4040:22 – 65 L/min
8040:90 – 280 L/min
__________________________________________________________________________________
Active Area
|
2540 |
4040 |
8040 |
31mil |
1.6 m2 |
6.1 m2 |
28 m2 |
46mil |
/ |
4.7 m2 |
23 m2 |